Syringe Pump SP-500II
Product type
SP-500II
Maximum injection rate
1500ml/h (Different injectors have different maximum rate.)
Range of flow rate
5ml injector: 0.1-100ml/h
10ml injector: 0.1-200ml/h
20ml injector: 0.1-400ml/h
30ml injector: 0.1-600ml/h
50ml injector: 0.1-1500ml/h
Injection increment
0.1ml/h
Bolus rate
5ml injector: 100ml/h
10ml injector: 200ml/h
20ml injector: 400ml/h
30ml injector: 400-600ml/h
50ml injector: 400-1500ml/h
Injection mode selection
1. Rate mode 2. Time mode 3. Body Weight mode
Rate mode
Speed: 0.1-1500ml/h (maximum value depends on the injector specifications)
Time mode
Time:1~2000 minutes
Accumulated injection volume: 0.1-999.9ml
Body Weight mode
Weight: 0.1~300.0kg
Drug: 0.1~999.9(mg)
Volume: 0.1~999.9ml
Dose: 0.1¡«9999.9(restricted to unit, drug, solution, weight and injector specification).
Unit: mg/kg/h, ug/kg/min
KVO rate
Adjustable range: 0.1ml/h¡«5.0ml/h (begin the KVO function under the occlusion situation) ; pressing STOP key to cancel the KVO function when it is unnecessary in use.
IP grade
IP21
Injection pressure
The maximum pressure is 0.3Mpa, Occlusion alarm pressure value is 40kPa¡«160kPa when pressure value is minimum, injection rate is 25ml/h, the longest alarm time is 10 minutes. When pressure value is minimum, injection rate is 5ml/h, the longest alarm time is 10 minutes.
Preset volume
0.1ml-9999.9ml
Preset time
0~99 hours, 0~59 minutes
Accumulated injection volume
0.1ml-9999.9ml
Accuracy
¡À3£¥
Power supply
AC 100¡«220V£¬50/60Hz
Battery
Rechargeable lithium polymer battery, 7.4 V, 1600mAh.
Maximum power consumption
25VA, running more than 2 hours at the rate of 25ml/h after being fully charged.
Battery charge
When syringe pump is connected to AC power, the battery will automatically recharge. (about 8¡«14 hours to recharge fully.)
Fuses
T2AL250V¡«
Displayed information
Flow rate; accumulated injection volume; injector specification; battery capacity; bed No.; AC power indicator, operation indication, etc.
State indication information
Stop, inject, bolus, KVO (stop flashing, the other indicators flash by turns.)
Alarm information
near completion, Over, occlusion, low battery, abnormal 1 (communications failure), abnormal 2 (pump stuck), abnormal 3 (wrong parameter), volume limited alarm, no AC power
Maximum size of the outer shell
288¡Á130¡Á122 mm£¨length¡Áwidth¡Áheight£©,
Maximum weight       
£¼3.0kg
Classification
Class¢ò, Type BF
Shell material
ABS plastic
Operating conditions
Environment temperature 5¡æ~40¡æ, air pressure 80kPa ~106kPa£¬relative humidity ¡Ü80%
Storage conditions
Environment temperature -40¡æ~55¡æ, air pressure 50kPa ~106kPa£¬relative humidity ¡Ü95%
Applicable syringes
5ml¡¢10 ml¡¢20 ml¡¢30ml¡¢50 ml syringes 
Electrical safety
In accordance with the stipulation of GB9706.1-1995
Applied standards
According to the stipulation of YZB/Yue 001-2008

 