stevenmyh

  HOME  |  ABOUT US  |  PRODUCTS  |  SUPPORT  |  NEWS  |  CONTACT US
 

Ultrasound Scanner
Digital Ultrasound System
Syringe Pump
Infusion Pump
Medical Ventilator
Patient Monitor
Electrocardiograph
Fingertip pulse oximeter
Biochemistry Analyzer
Fetal monitor

LATEST NEWS
¡¤ authentication (Grow With Us)
¡¤ Curbing Rad Residents' Graveya
¡¤ Red Wine Found to Prevent Radi
¡¤ ExportBureau


 
PRODUCTS  
Portable Ventilator 100C

100C Portable Ventilator 

100C Ventilators can be used for pediatric and adult patients.
Used for first aid, ambulance and patients transport within hospital.
use for first aid
use for ambulance
use for patients transport within hospital

 Physical Specifications

 Dimensions

Carrying packages Dimensions Packaging Dimensions

 Width:    300mm

Width:    460mm Width:    620mm

 Depth:    160mm

Depth:    200mm Depth:    240mm

Height:    230mm

Height:    400mm

Height:    410mm

Weight    3Kg

Weight    7Kg

Weight    11Kg

 

 Environmental Specifications

Operating Requirements

Storage/Shipping Requirements

Temperature:            5 to 40oC 

Temperature:            -20 to 70oC 

Relative Humidity:     less than  80%

Relative Humidity:        less than 93%

The atmosphere pressure: 70 to 106 kPa

The atmosphere pressure: 70 to 106 kPa

 Electrical Specifications

Input Voltage Requirements

 AC Voltage:   110V~240V

 DC Voltage:   12V
 Inlet Battery:12V , 2Ah (Can be used for 8 hours)

 Frequency:     50Hz/60Hz

 Power:             2A

 Pneumatic Specifications

Pneumatic Specifications 

Oxygen Inlet

Pressurized Oxygen:   0.4MPa medical oxygen or use 2L oxygen cylinder (Choice of suppliers)

 Performance Specification And Tolerances

 Controls 

    

 Power 

  ON/OFF

 Modes

  CMV(IPPV)   A/C(SIPPV)   SIMV   SPONT  PEEP(Choice of suppliers)

 Tidal Volume   

 50~1200ml

 Breath Rate

 5~60 bpm 

 PEEP 

  0~2KPa 

 O2%  

   45~90% 

Sigh   

1~10 per 100 breath

Peep  

10-60 hpa  (Choice of suppliers)

Trigger Level   

-10~0hpa

Over Pressure Relief   

<6kpa 

  Alarms and Indicators            

 High Pressure Alarm Limit 

2~6kpa    flash, red indicator 

 Low Pressure Alarm Limit   

0.  2~2kpa    Red indicator 

Alarm Silence  

120 sec

  Monitors            

Tidal Volume 

 

 Total Breath Rate    

 

Main Circuit Pressure

 

Wave Display 

Main Circuit Pressure

 What Is Provided            

 Part Name 

Number 

Specification  

  Ventilator 

 1

    

 Oxygen Cylinder

 1

2.5L can be used for 1 hour

 Breath Circuit

 1

1.2m

 Carrying Package

 1

all parts in it

 Breath Value

 1

   

 Mask 

1

   

Charger

1

    

Battery

1

Can be used for 8 hours

Wrench

1

     

Oxygen Pressure Reducer

1

For Nomal Oxygen Cylinder

Lung Simulators

1

   

Hand Book

1

    

CD For Operation